Testing Scope

A list of testing methods, materials or products, and test types available at GIS Laboratory.

Accreditation Scope - Location 1
Testing MethodMaterial/ProductType of Test
ASTM D97-17b:2022, D130 : 2019, D874:2023 ; ASTM D445:2021, ASTM D92:2018, ASTM D2896:2021, SNI 7069.1-20204-stroke gasoline engine lubricating oil for motor vehiclesPour Point, Copper test, Sulfated Ash, Kinematic Viscosity 100 °C, Total Base Number, Flashpoint COC
ASTM D97-17b:2022, D130 : 2019, D874:2023 ;ASTM D445:2021, ASTM D92:2018, ASTM D2896:2021; SNI 7069.2-20214-stroke gasoline engine lubricating oil for motorcyclesPour Point, Copper test, Sulfated Ash, Kinematic Viscosity 100 °C, Total Base Number, Flashpoint COC
D874:2023 ; ASTM D445:2021, ASTM D92:2018, ASTM D2896:2021;SNI 7069.3-20202-stroke gasoline engine lubricating oil with air coolingAsh sulfated, Kinematic Viscosity 100 °C, Total Base Number, Flashpoint COC
D130 : 2019; ASTM D445:2021; ASTM D92:2018 ;SNI 7069.4-20202-stroke gasoline engine lubricating oil with water coolingCopper test, Kinematic Viscosity 100 °C, Flashpoint COC
ASTM D97-17b:2022, D130 : 2019, D874:2023 ; ASTM D445:2021, ASTM D92:2018, ASTM D2896:2021; SNI 7069.5-2021High-speed diesel engine lubricating oilPour Point, Copper test, Sulfated Ash, Kinematic Viscosity 100 °C, Total Base Number, Flashpoint COC
D130 : 2019 ; ASTM D445:2021, ASTM D92:2018; SNI 7069.6-2021Manual transmission and differential gear lubricating oil for motor vehiclesCopper test, Kinematic Viscosity 100 °C, Flashpoint COC
D130 : 2019 ;ASTM D445:2021, ASTM D92:2018; ASTM D4052:2022; SNI 7069.7-2021Automatic transmission lubricating oilCopper test, Kinematic Viscosity 100 °C, Flashpoint COC, Density
D130 : 2019 ;ASTM D445:2021, ASTM D92:2018; SNI 7069.9-2016Anti-wear industrial hydraulic lubricating oilCopper test, Kinematic Viscosity 40 °C, Flashpoint COC
D130 : 2020 ; ASTM D445:2021, ASTM D92:2018; SNI 7069.10-2017Enclosed industrial gear lubricating oilCopper test, Kinematic Viscosity 40 °C, Flashpoint COC
ASTM D97-17b:2022, D130 : 2019, D874:2023 ; ASTM D445:2021, ASTM D92:2018, ASTM D2896:2021; SNI 7069.11-2018Medium-speed diesel engine lubricating oilPour Point, Copper test, Sulfated Ash, Kinematic Viscosity 100 °C, Total Base Number, Flashpoint COC
ASTM D97-17b:2022, D130 : 2019, D874:2023 ;ASTM D445:2021, ASTM D92:2018, ASTM D2896:2021; SNI 7069.12-2018Low-speed diesel engine lubricating oilPour Point, Copper test, Sulfated Ash, Kinematic Viscosity 100 °C, Total Base Number, Flashpoint COC
Accreditation Scope - Location 2
Testing MethodMaterial/ProductType of Test
AOCS Official Method Ca 3a-46, Revised 2021Crude Palm OilImpurity content
AOCS Official Method Cd 1d-92, Revised 2022Iodine value
MPOB-K1.1 2024Palm KernelImpurity content
MPOB-K.6 2024Moisture and volatile matter content
AOCS Official Method Ca2c-25, 2017RBD Palm OleinMoisture and volatile matter content
AOCS Official Method Ca 3a-46, Revised 2021Impurity content
AOCS Official Method Cd 1d-92, Revised 2022Iodine value
AOCS Official Method Ca 5a-40, 2017Free Fatty Acid (FFA)
SNI 2803:2012 Clause 6.4.2Solid NPK fertilizerPotassium as K2O
SNI 2803:2012Total N, P2O5, and K2O content
SNI 2803:2012 Clause 6.6.1Mercury (Hg)
SNI 2803:2012 Clause 6.6.2Cadmium (Cd)
SNI 2803:2012 Clause 6.6.3Lead (Pb)
SNI 2803:2012 Clause 6.7Arsenic (As)
SNI 281:2010, clause 6.4Urea fertilizerDetermination of granule/prill size. Size (1.00 mm - 3.35 mm & 2.00 mm - 4.75 mm
SNI 02-2805-2005 / AOAC Official Method 22nd, 2023 clause 2.6.37KCl fertilizer (Muriate of Potash)K2O content
SNI 02-2805-2005 Clause 6.2 / AOAC Official Method 22nd, 2023 clause 2.2.01Moisture content
SNI 02-3776-2005 Clause 6.1.1/ AOAC Official Method 22nd, 2023 clause 2.3.01 and 2.3.02Natural phosphate fertilizer for agricultureTotal P2O5
SNI 02-3776-2005 Clause 6.2 / AOAC Official Method 22nd, 2023 clause 2.2.01Moisture content
SNI 02-1760-2005 Clause 6.4 / AOAC Official Method 22nd, 2023 clause 2.2.01Ammonium sulfate fertilizer (ZA)Moisture content
SNI 02-0086-2005 Clause 6.1.1/ AOAC Official Method 22nd, 2023 clause 2.3.01 and 2.3.02TSP fertilizerP2O5 Total (dry basis)
SNI 02-0086-2005 Clause 6.1.3 / AOAC Official Method 22nd, 2023 clause 2.3.06 and 2.3.09Water-soluble P2O5 (dry basis)
SNI 02-0086-2005 Clause 6.3 / AOAC Official Method 22nd, 2023 clause 2.2.01Moisture content
SNI 02-3769-2005, clause 6.3SP36 fertilizerFree acid content as H3PO4 (dry basis)
SNI 9088:2022, Appendix A.4.1Red palm cooking oilCadmium (Cd)
SNI 9088:2022, Appendix A.4.1Lead (Pb)
SNI 7709:2019, Appendix A.9.1Palm cooking oilCadmium (Cd)
SNI 7709:2019, Appendix A.9.1Lead (Pb)
SNI 02-4959-1999Borate fertilizerBoron oxide (B2O3)
SNI 02-4959-1999 (for intended use only)Sulfatee (SO4)
SNI 02-4959-1999 (for intended use only)Cadmium (Cd)
AOAC 22nd edition, 2023 clause 2.2.01Moisture content
SNI 02-2807-1992, Clause 5.1Kieserite fertilizerMagnesium content as MgO
SNI 02-2807-1992, Clause 5.2Sulfur content as S
SNI 02-2807-1992, Clause 5.3Moisture content
ASTM D 5185-184-stroke gasoline engine lubricating oil for motor vehiclesCalcium (Ca), Magnesium (Mg), Zinc (Zn)
ASTM D 4951-14 (Reapproved 2019)Phosphorus (P), Sulfur (S)
ASTM D 5185-184-stroke gasoline engine lubricating oil for motorcyclesCalcium (Ca), Magnesium (Mg), Zinc (Zn)
ASTM D 4951-14 (Reapproved 2019)Phosphorus (P)
ASTM D 5185-182-stroke gasoline engine lubricating oil with air coolingCalcium (Ca)
ASTM D 5185-18High-Speed Diesel Engine Lubricating OilCalcium (Ca), Magnesium (Mg), Zinc (Zn)
ASTM D 4951-14 (Reapproved 2019)Phosphorus (P), Sulfur (S)
ASTM D 5185-18Automatic transmission lubricating oilCalcium (Ca), Magnesium (Mg), Zinc (Zn)
ASTM D 4951-14 (Reapproved 2019)Phosphorus (P), Sulfur (S)
ASTM D 5185-18Industrial lubricant (medium-speed diesel engine lubricating oil)Calcium (Ca), Magnesium (Mg), Zinc (Zn)
ASTM D 5185-18Industrial lubricant (low-speed diesel engine lubricating oil)Calcium (Ca), Magnesium (Mg), Zinc (Zn)
Accreditation Scope - Water & Environment
Testing MethodMaterial/ProductType of Test
SNI 06-6860-2002River water, lake water, estuary water, swamp water, aquifer water, pond water, spring water, reservoir water, well waterOdor
SNI 6989.80:2011Color
SNI 6989.11:2019pH
SNI 06-698.-23-2005Temperature
SNI 6989.27:2019Total dissolved solids (TDS)
SNI 6989.3:2019Total suspended solids (TSS)
SNI 6989.2:2019Chemical oxygen demand (COD)
SNI 6989.20:2019Sulfate
SNI 6989.19:2009Chloride
SNI 06-6989.9-2004Nitrite
SNI 06-6989.30-2005Ammonia
SNI 06-6989.29-2005Fluoride
SNI 6989.71:2009Hexavalent chromium
SNI 06-6989.51-2005MBAS / total detergent
SNI 6989.10-2011Oil and grease
SNI 06.6989.12-2004Hardness
SNI 6989-82:2018Dissolved barium (Ba)
SNI 6989-82:2018Dissolved boron (B)
SNI 6989-82:2018Dissolved iron (Fe)
SNI 6989-82:2018Dissolved cadmium (Cd)
SNI 6989-82:2018Dissolved cobalt (Co)
SNI 6989-82:2018Dissolved manganese (Mn)
SNI 6989-82:2018Dissolved nickel (Ni)
SNI 6989-82:2018Dissolved zinc (Zn)
SNI 6989-82:2018Dissolved copper (Cu)
SNI 6989-82:2019Dissolved chromium (Cr)
SNI 6989-82:2018Dissolved lead (Pb)
SNI 06-6989.23-2005Clean waterTemperaturee
SNI 6989.27:2019Total dissolved solids (TDS)
SNI 6989.80:2011Color
SNI 06-6860-2002Odor
SNI 6989.11:2019pH
SNI 06-6989.9-2004Nitrite
SNI 6989.71:2009Chromium valence 6 (Cr6+)
SNI 6989-82:2018Dissolved iron (Fe)
SNI 6989-82:2018Dissolved manganese (Mn)
SNI 6989.11:2019WastewaterpH
SNI 06-6989.23-2005Temperaturee
SNI 6989.27:2019Total dissolved solids (TDS)
SNI 6989.3:2019Total suspended solids (TSS)
SNI 6989.15:2019Chemical oxygen demand (COD)
SNI 6989.20:2019Sulfate
SNI 06-6989.9-2004Nitrite
SNI 06-6989.30-2005Ammonia
SNI 6989-82:2018Total barium (Ba)
SNI 6989-82:2018Dissolved iron (Fe)
SNI 6989-82:2018Total cadmium (Cd)
SNI 6989-82:2018Total cobalt (Co)
SNI 6989-82:2018Dissolved manganese (Mn)
SNI 6989-82:2018Total nickel (Ni)
SNI 6989-82:2018Total zinc (Zn)
SNI 6989-82:2018Total copper (Cu)
SNI 6989-82:2019Total lead (Pb)
SNI 6989-82:2020Total chromium (Cr)
SNI 6989.71:2009Hexavalent chromium
SNI 6989.10-2011Oil and grease
SNI 06-6989.5-2005MBAS / total detergent
SNI 3554:2015 Clause 3.2.1 / SNI 3553:2015 / SNI 6241:2015Mineral water / demineralized waterOdor and taste
SNI 3554:2015 Clause 3.2.3 / SNI 3553:2015 / SNI 6241:2015Color
SNI 3554:2015 Clause 3.3 / SNI 3553:2015 / SNI 6241:2015pH
SNI 3554:2015 Clause 3.5 / SNI 3553:2015 / SNI 6241:2015Dissolved substances
SNI 3554:2015 Clause 3.11 / SNI 3553:2015 / SNI 6241:2015Sulfate
SNI 3554:2015 Clause 3.12 / SNI 3553:2015 / SNI 6241:2015Chloride
SNI 3554:2015 Clause 3.8 / SNI 3553:2015 / SNI 6241:2015Nitrate
SNI 3554:2015 Clause 3.9 / SNI 3553:2015 / SNI 6241:2015Nitrite
SNI 3554:2015 Clause 3.10 / SNI 3553:2015 / SNI 6241:2015Ammonium (NH4)
SNI 3554:2015 Clause 3.13 / SNI 3553:2015 / SNI 6241:2015Fluoride
SNI 3554:2015 Clause 3.26.8 / SNI 3553:2015 / SNI 6241:2015Total barium (Ba)
SNI 3554:2015 Clause 3.26.8 / SNI 3553:2015 / SNI 6241:2015Total boron (B)
SNI 3554:2015 Clause 3.26.8 / SNI 3553:2015 / SNI 6241:2015Total arsenic (As)
SNI 3554:2015 Clause 3.26.8 / SNI 3553:2015 / SNI 6241:2015Total iron (Fe)
SNI 3554:2015 Clause 3.26.8 / SNI 3553:2015 / SNI 6241:2015Total cadmium (Cd)
SNI 3554:2015 Clause 3.26.8 / SNI 3553:2015 / SNI 6241:2015Total manganese (Mn)
SNI 3554:2015 Clause 3.26.8 / SNI 3553:2015 / SNI 6241:2015Total chromium (Cr)
SNI 3554:2015 Clause 3.26.8 / SNI 3553:2015 / SNI 6241:2015Total copper (Cu)
SNI 3554:2015 Clause 3.26.8 / SNI 3553:2015 / SNI 6241:2015Total lead (Pb)
SNI 3554:2015 Clause 3.21.2 / SNI 3553:2015 / SNI 6241:2015Total silver (Ag)
SNI 3554:2015 Clause 3.26.8 / SNI 3553:2015 / SNI 6241:2015Total selenium (Se)
SNI 3554:2015 Clause 3.26.8 / SNI 3553:2015 / SNI 6241:2015Total cobalt (Co)
SNI 3554:2015 Clause 3.26.8 / SNI 3553:2015 / SNI 6241:2015Total zinc (Zn)
SNI 3554:2015 Clause 3.27.2 / SNI 3553:2015 / SNI 6241:2015Detergent
SNI 3554:2015 Clause 3.6 / SNI 3553:2015 / SNI 6241:2015Organic matter (KMnO4 value)
SNI 6989-23-2005Drinking waterTemperaturee
SNI 06.6989.12-2004Hardness
SNI 6989.71:2009Chromium valence 6 (Cr6+)
SNI 8995:2021River water, lake water, estuary water, swamp water, aquifer water, pond water, spring water, reservoir water, well waterWater test sample collection for physical and chemical testing
SNI 8990:2021WastewaterWater test sample collection for physical and chemical testing
Accreditation Scope - Air & Emissions
Testing MethodMaterial/ProductType of Test
SNI 7119-7:2017Ambient airSulfur dioxide (SO2)
SNI 7119-2:2017Nitrogen dioxide (NO2)
SNI 19-7119.1-2005Ammonia (NH3)
SNI 7119-3:2017Dust particulate (TSP) 24 hours
SNI 7119-15:2016Dust particulate (PM10) 24 hours
SNI 7119-14:2016Dust particulate (PM2.5) 24 hours
SNI 7119-8:2017Ozone (O3)
SNI 7119-4:2017 (ICP-OES)Lead (Pb)
SNI 8427:2017Noise level 24 hours
SNI 19-7119.6-2005Determination of sampling locations for ambient air quality monitoring
SNI 19-7119.9-2005Determination of sampling locations for roadside air quality monitoring
SNI 19.7117.11-2005Stationary source emissionsOpacity
PO-GIS-ESTB-001 (Direct Reading)Nitrogen dioxide (NO2)
PO-GIS-ESTB-001 (Direct Reading)Sulfur dioxide (SO2)
PO-GIS-ESTB-001 (Direct Reading)Sulfur (H2S)
PO-GIS-ESTB-001 (Direct Reading)Nitrogen oxide (NO)
PO-GIS-ESTB-001 (Direct Reading)Oxygen (O2)
PO-GIS-ESTB-001 (Direct Reading)Carbon dioxide (CO2)
PO-GIS-ESTB-001 (Direct Reading)Carbon monoxide (CO)
PO-GIS-ESTB-001 (Direct Reading)Methane (CH4)
SNI 7117.13-2009Determination of locations and traverse points for particulate and linear velocity sampling
SNI 7117.14-2009Linear velocity
SNI 7117.15-2009Determination of dry molecular weight (flue gas)
SNI 7117.16-2009Moisture content (% volume)
SNI 7117.17-2009Particulate by isokinetic sampling
SNI 7119-7:2017, SNI 7119-2:2017, SNI 19-7119.1-2005, SNI 7119-3:2017, SNI 7119-15:2016, SNI 7119-14:2016, SNI 7119-8:2017, SNI 7119-4:2017, SNI 8427:2017Ambient airAmbient air test sample collection
SNI 7117.13-2009, SNI 7117.14-2009, SNI 7117.15-2009, SNI 7117.16-2009, SNI 7117.17-2009, PO-GIS-ESTB-001 (Direct Reading)Stationary source emission air (stack)Stationary source emission air sample collection (stack)
Accreditation Scope - Sprayer Equipment
Testing MethodMaterial/ProductType of Test
Plant maintenance equipment - electric knapsack sprayerVerification test
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.2Dimension and specification measurement:
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.3 (Dimensions)Tank length
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.3 (Dimensions)Tank width
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.3 (Dimensions)Height including pump and battery compartment
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.4 (Gravimetry)Empty weight
SNI 8485 : 2023, Clause 6.3.1.2cTank capacity
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.3 (Dimensions)Tank wall thickness
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.3 (Dimensions)Filling filter funnel diameter
SNI 8485 : 2023, Clause 6.3.1.1aFilling filter opening size
SNI 8485 : 2018, Clause 6.3.1.1bBottom filter opening size (tank base)
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.3 (Dimensions)Hose length
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.3 (Dimensions)Hose outside diameter
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.3 (Dimensions)Spray pipe length
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.3 (Dimensions)Spray pipe outside diameter
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.3 (Dimensions)Shoulder strap width
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.3 (Dimensions)Shoulder pad foam thickness
Tank
SNI 8485 : 2023, Clause 6.3.1.2aMade of stainless steel or plastic (HDPE)
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.1 (Visual)For plastic tanks, the liquid filling limit and surface must be clearly visible during filling.
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.3 (Dimensions)Equipped with a filling filter funnel with a minimum diameter of 50 mm, with filter opening size from 0.1 mm to 1.0 mm
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.3 (Dimensions)The tank has a bottom filter opening (tank base), with mesh size from 32 mesh to 48 mesh
Battery and pump compartment
SNI 8485 : 2023, Clause 6.3.1.3Made of stainless steel with minimum thickness of 1.0 mm, or plastic (HDPE) with minimum thickness of 2.5 mm
Tank lid
SNI 8485 : 2023, Clause 6.3.1.2bThe tank lid must be easy to close by an operator wearing gloves and must have an effective seal.
Spray pipe
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.2 (Visual)The spray pipe must be easy to detach from the connection so it can be stored when not in use.
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.3 (Visual)The spray pipe must not have sharp bends in any normal working position
Nozzle
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.4 (Visual)At least 2 nozzle types must be provided with spray patterns: type F (flat fan), type FE (flat fan), or cone type
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.5 (Visual)The nozzle body must have standard-type threads
Spray hose on/off valve
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.6 (Visual)Pressure lines must be equipped with valves that can close quickly (instantly).
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.7 (Visual)The valve must close when released and must not be locked when in the open position
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.8 (Visual)Unintended opening of the shut-off valve must be minimized, for example due to force or the locking component.
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.9 (Visual)The shut-off valve must open and close properly, and must be marked open and closed.
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.10 (Visual)The shut-off valve handle must be comfortable and easy to grip by an operator wearing gloves.
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.11 (Visual)The shut-off valve must be operable comfortably without tiring the operator's hand.
Spray hose
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.12 (Visual)The hose material may be rubber or synthetic material
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.13 (Visual)The hose is connected to the connector, hose screw cap, and clamp.
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.14 (Visual)Rubber hose material may have one or more reinforced fiber layers.
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.15 (Visual)Threaded connections must be sufficiently strong, capable of being tightened by thumb, and must not leak when operated at maximum pressure.
Shoulder strap
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.16 (Visual)The shoulder strap and shoulder pad must be strong enough to withstand the load and made of non-absorbent material (polyester braid or polypropylene multi-filament yarn)
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.17 (Visual)At least one shoulder strap must be provided, complete with a part that can be quickly attached and released with one hand
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.18 (Visual)It must not loosen by itself, for example due to gravity or movement
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.19 (Visual)It must be adjustable according to the operator's body posture.
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.20 (Visual)A fastening-type mechanism must be available for quick release in an emergency.
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.21 (Visual)There must be no damage to the shoulder strap and fixation points that reduces function as a consequence of the shoulder strap durability test.
Filter
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.3 (Dimensions)The filter opening size must be smaller than the narrowest diameter of the smallest nozzle size used.
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.22 (Visual)The upper filter must be made of stainless steel or plastic, and the filter at the tank base must be made of stainless steel and must be removable, replaceable, and cleanable.
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.5.23 (Visual)The filter design must allow the tank to be filled quickly without spilling and must be equipped with air ventilation
Connectors and couplings
SNI 8485 : 2023, Clause 6.3.1 and PO-GIS-PTN-001 Clause 5.1.3 (Dimensions)The diameter and thread size must be the same
Performance test
SNI 8485 : 2023 Clause 6.3.2.1Spray discharge test
SNI 8485 : 2023 Clause 6.3.2.7Shoulder strap and fixation point test
SNI 8485 : 2018 Clause 6.2.4.1.4External surface deposit volume test
SNI 8485 : 2018 Clause 6.2.4.1.5Total residual liquid volume test
SNI 8485 : 2023 Clause 6.3.2.6Stability test
SNI 8485 : 2023 Clause 6.3.2.2Sprayer tank fill scale test
SNI 8485 : 2018 Clause 6.2.4.1.8Total volume test
SNI 8485 : 2018 Clause 6.2.4.1.9Filling rate test
SNI 8485 : 2018 Clause 6.2.4.1.10Emptying test
SNI 8485 : 2023 Clause 6.3.2.9Impact test
SNI 8485 : 2023 Clause 6.3.2.3Spraying test
SNI 8485 : 2023 Clause 6.3.5Serviceability test
SNI 8485 : 2023 Clause 6.3.3Continuous load test
SNI 8485 : 2023 Clause 6.3.4Conformity test
No data found. Please try another keyword.